This series covers a frequency range of 10Hz to 30MHz (graded by model), with switchable output impedance of 25Ω/100Ω, paired with internal DC bias of -12V~+12V, adapting to diverse device characteristics. It supports meter mode (4 parameters displayed simultaneously), multi-step list testing (15 custom steps), and graphical analysis of frequency/level/bias scanning to intuitively present device characteristics. It has built-in 9-level sorting function and open/short/load calibration to ensure measurement accuracy. It has strong storage and expansion capabilities: internal storage for 100 groups of meter configurations and 50 groups of multi-step schemes; USB expansion supports FAT32 format, enabling data and image saving and software upgrade. It has rich interfaces, including standard RS-232C, USB, and HANDLER, with optional GPIB and LAN, meeting automated integration and remote control needs, balancing professionalism and ease of use.
| Test parameter | |Z|, |Y|, C, L, X, B, R, G, D, Q, DCR, Vdc – Idc, ESR, μr, εr | |
| Test frequency | MCR-9005: 10Hz - 5MHz | MCR-9010: 10Hz - 10MHz | MCR-9020: 10Hz - 20MHz | MCR-9030: 10Hz - 30MHz | |
| Minimum resolution | 100mHz, 6-digit frequency input | |
| Accuracy | 7ppm±100mHz | |
| Basic measurement accuracy | 0.08% | |
| Measuring | Measurement mode | Meter mode, Multi-step list, Graphics scan |
| Measuring speed (fastest) | < 3ms | |
| AC Measuring | Test signal voltage range | 10mV - 2Vrms |
| Minimum voltage resolution | 1mV | |
| Voltage Accuracy | ALC OFF: 10% * Set voltage ±2mV | ALC ON: 5% * Set voltage ±2mV | |
| Test signal current range | 200μA - 200mArms | |
| Minimum resolution current | 10μA | |
| Current Accuracy | ALC OFF: 10% * Set current ±20μA | ALC ON: 5% * Set current ±20μA | |
| Output impedance | Switchable 25Ω, 100Ω | |
| Features | Calibration function | Open circuit / short circuit / load |
| Equivalent Circuit | Series, Parallel | |
| Equivalent model analysis | Three components (4 models), four components (3 models) (optional) | |
| Multi-step test | 15 test steps | |
| Built-in DC bias voltage | -12~+12V, 100Hz - 30MHz | |
| Storage | Internal storage memory | 100 groups of LCR meter setting files, 50 groups of multi-step test setup (each group have 15 test steps) |
| External USB memory | LCR meter setting files, BPM image, multi-groups of configuration file, scan image and data | |
| Parameter Measuring Range | |Z|, R, X | 0.000mΩ - 999.99MΩ |
| |Y|, G, B | 0.0000μS - 999.99kS | |
| Cs, Cp | 0.00000pF - 9999.99F | |
| Ls, Lp | 0.000nH - 9999.99kH | |
| D, Q | 0.00000 - 99999.99 | |
| θRAD | ±0.000000 - 3.14159 | |
| θDEG | ±0.000° - 180.000° | |
| Δ | ±0.00% - 9999.99% | |
| Rdc | 0.00mΩ - 99.999MΩ | |
| εr εr', μr μr' | 0 - 100000 | |
| Interface/Physical | I/O interface | HANDLER |
| Serial communication interface | USB, RS232, LAN | |
| Parallel communication interface | GPIB | |
| Display | 7.0 "TFT, 800*480 color display | |
| Operating environment | Temperature: 10℃ - 40℃, Humidity: ≤80%RH | |
| Input power supply | Voltage: 90 - 264Vac | Frequency: 47 - 63Hz | |
| Instrument size (W*H*D) | 359 * 147 * 343 mm | |
| PCLINK / CPK report environment | Optional | |
| Net weight (kg) | 3.95 | |
| Gross weight (kg) | 6.3 |