The MPB Series Bidirectional Programmable DC Power Supply is an advanced, microprocessor-controlled solution integrating bipolar power supply and regenerative load capabilities. Leveraging third-generation SiC technology, it delivers exceptional performance with bidirectional energy transfer, enabling seamless and fast switching between source and sink modes without voltage or current overshoot—ideal for testing energy storage devices like batteries and battery protection boards. With a high power density of up to 18KW in a compact 3U form factor, it offers a wide output range (up to 2250V) and supports multiple operating modes (CV/CC/CP), along with adjustable rise and fall times for voltage, current, and power. Its energy regeneration efficiency reaches 95%, reducing operational costs and carbon footprint by feeding excess energy back to the grid, while the integrated power and load design saves valuable test system space. Equipped with a suite of advanced features, the MPB Series ensures precision, safety, and flexibility for diverse testing scenarios. It includes a built-in function generator for custom waveforms, sequence testing (50 sequences with 20 steps each) for automated aging and stress tests, and battery simulation with 10+ preloaded battery curves plus custom curve support. Comprehensive protection mechanisms (OVP/OCP/OPP/OTP, etc.) safeguard both the power supply and connected devices, while remote voltage drop compensation enhances measurement accuracy for long-lead applications. The user-friendly interface features a high-brightness color LCD touchscreen, and seamless connectivity via RS232/RS485/LAN/CAN interfaces (supports SCPI and Modbus protocols) enables easy local or remote control. Additionally, it supports parallel operation of up to 36 units for expanded power capacity, making it a versatile choice for research labs, production lines, and industrial testing.
| Model | Voltage | Current | Power |
|---|---|---|---|
| MPB-5000S-100-170 | 0~100V | -170~170A | -5kW~5kW |
| MPB-5000S-300-75 | 0~300V | -75~75A | -5kW~5kW |
| MPB-5000S-500-40 | 0~500V | -40~40A | -5kW~5kW |
| MPB-5000S-750-25 | 0~750V | -25~25A | -5kW~5kW |
| MPB-10000S-100-340 | 0~100V | -340~340A | -10kW~10kW |
| MPB-10000S-300-150 | 0~300V | -150~150A | -10kW~10kW |
| MPB-10000S-500-80 | 0~500V | -80~80A | -10kW~10kW |
| MPB-10000S-750-50 | 0~750V | -50~50A | -10kW~10kW |
| MPB-10000S-1000-40 | 0~1000V | -40~40A | -10kW~10kW |
| MPB-12000S-300-150 | 0~300V | -150~150A | -10kW~10kW |
| MPB-12000S-500-80 | 0~500V | -80~80A | -10kW~10kW |
| MPB-12000S-800-50 | 0~800V | -50~50A | -10kW~10kW |
| MPB-12000S-1000-30 | 0~1000V | -30~30A | -10kW~10kW |
| MPB-12000S-1500-25 | 0~1500V | -25~25A | -10kW~10kW |
| MPB-15000S-100-510 | 0~100V | -510~510A | -15kW~15kW |
| MPB-18000S-100-510 | 0~100V | -510~510A | -18kW~18kW |
| MPB-18000S-300-225 | 0~300V | -225~225A | -18kW~18kW |
| MPB-18000S-500-120 | 0~500V | -120~120A | -18kW~18kW |
| MPB-18000S-750-75 | 0~750V | -75~75A | -18kW~18kW |
| MPB-18000S-1500-40 | 0~1500V | -40~40A | -18kW~18kW |
| MPB-18000S-2250-25 | 0~2250V | -25~25A | -18kW~18kW |
| MPB-20000S-100-510X | 0~100V | -510~510A | -20kW~20kW |
| MPB-20000S-300-225X | 0~300V | -225~225A | -20kW~20kW |
| MPB-20000S-500-160 | 0~500V | -160~160A | -20kW~20kW |
| MPB-20000S-750-80 | 0~750V | -80~80A | -20kW~20kW |
| MPB-20000S-1000-80 | 0~1000V | -80~80A | -20kW~20kW |
| Input | Input range | Three phase three wire+PE | AC:342 ~ 528V | 47 ~ 63Hz |
| Performance | Power factor | 0.99 |
| Feedback efficiency | 93% | |
| Dynamic response time | Rise time: ≤1.5ms | Source load switching: 30ms(10%~90%) / 2ms(+90%~-90%) | |
| Output | Output range | Voltage: 0V – rated | Current: 0A rated | Power: 0W rated |
| Accuracy | Set accuracy | Voltage: ≤0.10%FS | Current: ≤0.20%FS | Power: ≤1.00%FS |
| Read back value accuracy | Voltage: ≤0.10%FS | Current: ≤0.20%FS | Power: ≤1.00%FS | |
| Resolution | Set resolution | Voltage: 0.01V | Current: 0.01A | Power: 0.001kW |
| Read back value resolution | Voltage: 0.01V | Current: 0.01A | Power: 0.001kW | |
| Regulation | Power regulation | Voltage: ≤0.02%FS | Current: ≤0.05%FS |
| Load Regulation | Voltage: ≤0.05%FS | Current: ≤0.15%FS | |
| Protection | Protection function | OVP, OCP, OPP, OTP, Vsense reverse, input over/undervoltage |
| Feature | Parallel / Comm. | Support multiple parallel outputs | RS232, RS485, LAN, CAN (optional) |
| Environment | Operating / Storage Temp | 0 ~ 40°C / -10°C ~ 70°C | Humidity 20% ~ 90%RH |