This series supports four static working modes: Constant Current (CC), Constant Voltage (CV), Constant Resistance (CR), and Constant Power (CP), as well as high-speed dynamic modes including step and pulse load change simulation, meeting complex testing scenario needs. It has functions such as battery discharge simulation, rapid OCP testing, programmable multi-group load switching, and automatic testing to adapt to diverse testing requirements. It comes with a standard RS-232 interface, optional GPIB interface, supporting Modbus protocol and SCPI specification commands, compatible with communication commands of similar products for easy remote control and system integration. It has built-in comprehensive protection mechanisms, including overvoltage (OV), overcurrent (OC), overpower (OP), overtemperature (OT), and reverse polarity protection, ensuring safe and stable testing processes.
| Model | Voltage | Current | Power |
|---|---|---|---|
| PEL-9150S1212 | 0-150V | 120A | 1200W |
| PEL-9150S1818 | 0-150V | 180A | 1800W |
| PEL-9150S2424 | 0-150V | 240A | 2400W |
| PEL-9150S3030 | 0-150V | 300A | 3000W |
| PEL-9150S6060 | 0-150V | 600A | 6000W |
| PEL-9150S9090 | 0-150V | 900A | 9000W |
| PEL-9150S120120 | 0-150V | 1200A | 12KW |
| PEL-9150S150150 | 0-150V | 1500A | 15KW |
| PEL-9150S180120 | 0-150V | 1200A | 18KW |
| PEL-9150S240120 | 0-150V | 1200A | 24KW |
| PEL-9150S300120 | 0-150V | 1200A | 30KW |
| PEL-9150S400120 | 0-150V | 1200A | 40KW |
| PEL-9600S124.8 | 0-600V | 48A | 1200W |
| PEL-9600S187.2 | 0-600V | 72A | 1800W |
| PEL-9600S249.6 | 0-600V | 96A | 2400W |
| PEL-9600S3012 | 0-600V | 120A | 3000W |
| PEL-9600S6024 | 0-600V | 240A | 6000W |
| PEL-9600S9036 | 0-600V | 360A | 9000W |
| PEL-9600S12048 | 0-600V | 480A | 12KW |
| PEL-9600S15060 | 0-600V | 600A | 15KW |
| PEL-9600S18072 | 0-600V | 720A | 18KW |
| PEL-9600S24096 | 0-600V | 960A | 24KW |
| PEL-9600S300120 | 0-600V | 1200A | 30KW |
| PEL-9600S400120 | 0-600V | 1200A | 40KW |
| PEL-9800S124.8 | 0-800V | 48A | 1200W |
| PEL-9800S187.2 | 0-800V | 72A | 1800W |
| PEL-9800S249.6 | 0-800V | 96A | 2400W |
| PEL-9800S3012 | 0-800V | 120A | 3000W |
| PEL-9800S6024 | 0-800V | 240A | 6000W |
| PEL-9800S9036 | 0-800V | 360A | 9000W |
| PEL-9800S12048 | 0-800V | 480A | 12KW |
| PEL-9800S15060 | 0-800V | 600A | 15KW |
| PEL-9800S18072 | 0-800V | 720A | 18KW |
| PEL-9800S24096 | 0-800V | 960A | 24KW |
| PEL-9800S300120 | 0-800V | 1200A | 30KW |
| PEL-9800S400120 | 0-800V | 1200A | 40KW |
| PEL-91200S3012 | 0-1200V | 120A | 3000W |
| PEL-91200S6024 | 0-1200V | 240A | 6000W |
| PEL-91200S9036 | 0-1200V | 360A | 9000W |
| PEL-91200S12048 | 0-1200V | 480A | 12KW |
| PEL-91200S15060 | 0-1200V | 600A | 15KW |
| PEL-91200S18072 | 0-1200V | 720A | 18KW |
| PEL-91200S24096 | 0-1200V | 960A | 24KW |
| PEL-91200S300120 | 0-1200V | 1200A | 30KW |
| PEL-91200S400120 | 0-1200V | 1200A | 40KW |
| General Series Specs | Display | 5-inch TFT color screen |
| A/D Converter | 16-bit A/D conversion chip | |
| Data Storage | 1000 sets of data storage capacity | |
| Protection | OP, OV, OC, OT and reverse polarity | |
| Interfaces | RS-232C standard, GPIB optional | |
| Dynamic Mode Rate | Up to 20KHz | |
| Load Modules | CC, CR, CV, CP, Dynamic (Step/Pulse/Ladder) | |
| Performance | CC Mode Accuracy | 0.05% + 0.1% FS to 0.1% + 0.1% FS (Depends on model) |
| CV Mode Accuracy | 0.05% + 0.05% FS | |
| CP Mode Accuracy | 0.2% + 0.2% FS | |
| CR Mode Accuracy | Vin/Rset*(0.2%) + 0.2%F.S to 0.2%I.F.S | |
| Dynamic Mode T1&T2 | 0.025-10mS to 1mS-30S | |
| Measurement | Voltage Accuracy | 0.025% + 0.05% FS |
| Current Accuracy | 0.05% + 0.1% FS | |
| Power Accuracy | 0.2% + 0.2% FS |