Matrix logo
PEL-9000S Series Programmable DC Electronic Load

PEL-9000SSeries Programmable DC Electronic Load

  • Power coverage: 1.2KW-40KW; Maximum current up to 1500A
  • Voltage range: 150V/600V/800V/1200V
  • Supports four modes: CV, CC, CR, and CP
  • Battery test function
  • Fast OCP test function

Want a custom configuration?

This series supports four static working modes: Constant Current (CC), Constant Voltage (CV), Constant Resistance (CR), and Constant Power (CP), as well as high-speed dynamic modes including step and pulse load change simulation, meeting complex testing scenario needs. It has functions such as battery discharge simulation, rapid OCP testing, programmable multi-group load switching, and automatic testing to adapt to diverse testing requirements. It comes with a standard RS-232 interface, optional GPIB interface, supporting Modbus protocol and SCPI specification commands, compatible with communication commands of similar products for easy remote control and system integration. It has built-in comprehensive protection mechanisms, including overvoltage (OV), overcurrent (OC), overpower (OP), overtemperature (OT), and reverse polarity protection, ensuring safe and stable testing processes.

ModelVoltageCurrentPower
PEL-9150S12120-150V120A1200W
PEL-9150S18180-150V180A1800W
PEL-9150S24240-150V240A2400W
PEL-9150S30300-150V300A3000W
PEL-9150S60600-150V600A6000W
PEL-9150S90900-150V900A9000W
PEL-9150S1201200-150V1200A12KW
PEL-9150S1501500-150V1500A15KW
PEL-9150S1801200-150V1200A18KW
PEL-9150S2401200-150V1200A24KW
PEL-9150S3001200-150V1200A30KW
PEL-9150S4001200-150V1200A40KW
PEL-9600S124.80-600V48A1200W
PEL-9600S187.20-600V72A1800W
PEL-9600S249.60-600V96A2400W
PEL-9600S30120-600V120A3000W
PEL-9600S60240-600V240A6000W
PEL-9600S90360-600V360A9000W
PEL-9600S120480-600V480A12KW
PEL-9600S150600-600V600A15KW
PEL-9600S180720-600V720A18KW
PEL-9600S240960-600V960A24KW
PEL-9600S3001200-600V1200A30KW
PEL-9600S4001200-600V1200A40KW
PEL-9800S124.80-800V48A1200W
PEL-9800S187.20-800V72A1800W
PEL-9800S249.60-800V96A2400W
PEL-9800S30120-800V120A3000W
PEL-9800S60240-800V240A6000W
PEL-9800S90360-800V360A9000W
PEL-9800S120480-800V480A12KW
PEL-9800S150600-800V600A15KW
PEL-9800S180720-800V720A18KW
PEL-9800S240960-800V960A24KW
PEL-9800S3001200-800V1200A30KW
PEL-9800S4001200-800V1200A40KW
PEL-91200S30120-1200V120A3000W
PEL-91200S60240-1200V240A6000W
PEL-91200S90360-1200V360A9000W
PEL-91200S120480-1200V480A12KW
PEL-91200S150600-1200V600A15KW
PEL-91200S180720-1200V720A18KW
PEL-91200S240960-1200V960A24KW
PEL-91200S3001200-1200V1200A30KW
PEL-91200S4001200-1200V1200A40KW
General Series SpecsDisplay5-inch TFT color screen
A/D Converter16-bit A/D conversion chip
Data Storage1000 sets of data storage capacity
ProtectionOP, OV, OC, OT and reverse polarity
InterfacesRS-232C standard, GPIB optional
Dynamic Mode RateUp to 20KHz
Load ModulesCC, CR, CV, CP, Dynamic (Step/Pulse/Ladder)
PerformanceCC Mode Accuracy0.05% + 0.1% FS to 0.1% + 0.1% FS (Depends on model)
CV Mode Accuracy0.05% + 0.05% FS
CP Mode Accuracy0.2% + 0.2% FS
CR Mode AccuracyVin/Rset*(0.2%) + 0.2%F.S to 0.2%I.F.S
Dynamic Mode T1&T20.025-10mS to 1mS-30S
MeasurementVoltage Accuracy0.025% + 0.05% FS
Current Accuracy0.05% + 0.1% FS
Power Accuracy0.2% + 0.2% FS