Matrix logo
PDS Series Programmable DC Power Supplies

PDSSeries Programmable DC Power Supplies

  • Voltage output range: 0~80V; Current output range: 0~60A; Maximum power coverage: 600W~900W
  • 100 groups of voltage and current storage and recall functions for efficient operation
  • Equipped with voltage compensation to eliminate line loss
  • Low resistance measurement function
  • Standard RS-232 and SENSE interfaces, optional analog control interface

Want a custom configuration?

The PDS Series programmable DC power supplies include models from PDS2030, PDS3020 to PDS8010, with voltage ranging from 0~15V to 0~80V and current from 0~10A to 0~60A, suitable for electronic development, device testing, and other scenarios. They support dual-mode parameter setting via a numeric keypad and knob, with 100 groups of voltage and current storage/recall functions for efficient operation. Practical designs include voltage compensation to eliminate line loss, precise output switch control, intelligent temperature-controlled fans balancing cooling and quietness, and encoder switch knobs with anti-misadjustment protection. Over-voltage/over-current/over-temperature protection builds a solid safety barrier. Standard RS-232 and SENSE interfaces are included, with optional analog control interfaces, adapting to production line testing and maintenance, laboratory research, new energy vehicle simulation, and automated integration testing scenarios. They provide reliable support for precise power supply testing in multiple fields, facilitating efficient completion of various experiments and production tasks.

ModelVoltageCurrentPower
PDS-20300-20V0-30A600W
PDS-30200-30V0-20A600W
PDS-60100-60V0-10A600W
PDS-15600-15V0-60A900W
PDS-30300-30V0-30A900W
PDS-60150-60V0-15A900W
PDS-80100-80V0-11A880W
Base SpecsRated input voltageAC220V±10%, 50/60Hz
RegulationPower effectVoltage: ≤0.01%+4mV | Current: ≤0.2%+3mA
Load effectVoltage: ≤0.1%+5mV | Current: ≤0.2%+5mA
Signal IntegrityRipple and noiseVoltage: 2mVrms, 30mVpp | Current: ≤10mArms
AccuracySetting precision (25±5℃)Voltage: ±(0.03% of reading+10mV) | Current: ±(0.3% of reading+10mA)
Accuracy of reading (25±5℃)Voltage: ±(0.02% of reading+5mV) | Current: ±(0.05% of reading+10mA)
ResolutionSetting resolution1mV / 1mA
PerformanceVoltage Recovery time≤1.5ms (50% load change)
Voltage Temperature coefficient≤300ppm/℃
ProtectionProtectionOLP, OVP, OCP, OTP, RP
FeaturesInterfaceStandard RS-232, support SCPI instruction set; analog control interface (optional)
Storage redeployment100 groups
EnvironmentOperating environmentIndoor use, altitude: ≤2000m, ambient temp: 0-40℃, RH: ≤80%, Install level: Ⅱ, Degree of pollution: 2
Storage environmentambient temp: -10-70℃, RH: ≤70%
PhysicalSize (WHD) / Net weight215*89*412 mm / 4.6kg(600W), 5.5kg(900W)
Accessoriesuser manual 1pc, power cord 1pc